F-gases and regulations
F-gases: what rules apply to your system?
Veyra Climate editorial team · Published 2 October 2026 · Updated 2 October 2026 · 6 min read
Contents
EU Regulation 2024/573 sets requirements for equipment containing fluorinated refrigerants.
Understanding the Core Principles of F-gas Regulation
The European Union has established specific rules, outlined in Regulation (EU) 2024/573, to manage the use of equipment containing fluorinated refrigerants, commonly known as F-gases [1]. These regulations are not merely administrative; they are designed to promote the responsible handling of substances that have an impact on the environment. As an operator or owner of climate control, refrigeration, or heat pump equipment, it is your responsibility to understand and comply with these requirements. The rules focus on preventing the release of these gases into theatmosphere through diligent maintenance, regular inspections, and thorough record keeping.
The central concept underpinning these rules is the CO₂ equivalent of the refrigerant in your system [2]. This is a crucial measure because it standardises the potential climate impact of different types of F-gases. Not all refrigerants are equal; some have a much higher global warming potential than others. Therefore, the regulations are not based simply on the weight of the gas in kilograms, but on its total potential environmental effect, expressed as a tonnage of carbon dioxide. This approach ensures that systems containing smaller amounts of more potent gases are subject to the same level of scrutiny as systems with larger quantities of less potent gases. Determining the CO₂ equivalent is the first essential step for any equipment operator, as it dictates the specific obligations that apply to your installation [1][2].
Mandatory Leak Checks: A Schedule for Compliance
One of the primary obligations for operators is the implementation of a regular leak check schedule. The purpose of these checks is to identify and repair any potential leaks before they result in a significant release of refrigerant. The frequency of these mandatory inspections is directly linked to the CO₂ equivalent of the refrigerant contained within your system [2]. It is a tiered system, meaning that as the potential environmental impact increases, so does the required frequency of checks.
The thresholds for these checks are clearly defined. For systems containing F-gases with a CO₂ equivalent of 5 tonnes or more, a leak check must be performed at least once every year. For systems containing 50 tonnes or more, the frequency increases to at least once every six months. For the largest systems, those containing 500 tonnes or more of CO₂ equivalent, checks are required on a quarterly basis, or at least once every three months [2]. It is vital for operators to accurately calculate their system's CO₂ equivalent to ensure they are adhering to the correct inspection schedule.
| CO₂ Equivalent Threshold | Minimum Leak Check Frequency |
|---|---|
| From 5 tonnes | Annually (once per year) |
| From 50 tonnes | Every six months (twice per year) |
| From 500 tonnes | Quarterly (four times per year) |
It is important to note that these checks must be carried out by certified personnel who have the correct training and equipment to perform the task effectively and safely.
A significant provision within the regulation allows for a reduction in the frequency of these mandatory checks. If your equipment is fitted with a suitable leak detection system, the required inspection frequency can be halved [2]. For instance, a system that would normally require an annual check would only need one every two years if it has an appropriate leak detector installed. Similarly, a system requiring checks every six months would move to an annual schedule. A "suitable" system is generally understood to be one that continuously monitors the equipment and provides an alert to the operator in the event of a leak. Investing in such a system can therefore offer both enhanced environmental protection and a reduction in routine compliance activities. However, it is important to be aware that exceptions and additional conditions may apply, depending on the specifics of your installation and the interpretation of the rules [2]. Professional guidance is recommended to confirm your exact obligations.
The Importance of Comprehensive Record Keeping
Beyond physical checks, the regulation places a strong emphasis on meticulous record keeping. Every operator of equipment subject to these rules must maintain a detailed logbook for each system. This log serves as the official history of the equipment, documenting all activities related to the fluorinated refrigerants it contains [2]. These records are not just an administrative task; they are a legal requirement and provide a complete chain of custody for the refrigerant, from its installation to its eventual recovery and disposal.
According to the available guidance, your records should contain clear and accurate information on several key points:
- Type and quantity of refrigerant: You must record the specific type of F-gas used in the system and the total quantity installed. This information is fundamental for calculating the CO₂ equivalent.
- Maintenance and service records: Any maintenance or servicing performed on the equipment must be logged. This includes the date of the work and details of the company and certified technician who carried it out.
- Leak check results: The dates and results of all mandatory leak checks must be recorded. If a leak was detected, the log should include details of the repair, the amount of refrigerant added after the repair, and the follow-up verification check.
- Recovered gas information: If refrigerant is removed from the system, whether during servicing or at the end of the equipment's life, the quantity of gas recovered must be recorded [2]. This demonstrates that the gas has been handled responsibly and not vented into the atmosphere.
Keep records of the type and quantity of refrigerant, maintenance, checks and recovered gas. The precise obligations depend on your equipment and current regulations [2].
This logbook must be kept up to date and be made available to authorities upon request for inspection purposes. The precise obligations for what must be recorded can vary depending on the specific type of equipment and the most current version of the regulations [2]. Maintaining a clear, organised, and complete logbook is a cornerstone of demonstrating compliance.
Your Responsibilities as an Equipment Operator
As the owner or operator of the equipment, the ultimate responsibility for compliance rests with you. This involves taking proactive steps to understand the regulations and ensure that all requirements are met. Your key duties include arranging for leak checks to be performed by certified professionals at the correct intervals and ensuring that a complete and accurate system logbook is maintained for all relevant equipment [1][2].
It is essential to engage with a certified climate installation and maintenance company. These specialists have the necessary knowledge of the regulations, the technical expertise to service your equipment correctly, and the proper certification to handle fluorinated refrigerants. They can perform the mandatory leak checks, carry out repairs, and help you maintain your records in a compliant manner. Attempting to service equipment or handle refrigerants without the proper certification is not only non-compliant but can also be unsafe and environmentally harmful. By establishing a service agreement with a reputable partner, you can ensure that your obligations are met consistently and professionally, providing you with peace of mind and safeguarding you from potential penalties associated with non-compliance. Always seek expert advice to fully understand how the F-gas regulations apply to your specific circumstances.
Sources
- [1]EUR-Lex, Verordening (EU) 2024/573 · accessed 2 October 2026
- [2]IPLO, F-gassen · accessed 2 October 2026
This article is for information only and does not create any legal rights.
Related serviceMaintenance and service
Related articles
F-gases and regulations · 6 min read
Mandatory leak checks: how often and why?
Leak checks limit refrigerant loss and help assess the condition of your system.
Read article →F-gases and regulations · 5 min read
R410A or R32: what about your existing air conditioning?
The industry is moving towards lower-impact refrigerants. An existing system does not necessarily need immediate replacement.